Drager Evita 4 Ventilator System

The Drager Evita 4 is time-cycled, constant-volume long-term ventilator. It was designed to meet the demanding requirements of the ICU environment by improving the interactions between patient, ventilator and clinician. The Evita 4 has a functional touch screen that continually provides the clinician information on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of the device. Unique features and modalities such as AutoFlow and APRV are standard on all Evita ventilators.

Description

Drager Evita 4 Ventilator System

Dimensions

  • OuteHeight: 11.4 inches (29 cm)
  • Width: 20.9 inches (53 cm)
  • Depth: 17.7 inches (45 cm)
  • Weight: 60 lbs. (27 kg)

Display

  • Type: Color TFT Color Display
  • Size: 6.5″ (diagonal)

 

Ventilation Modes

  • CMV (Continuous Mandatory)
  • SIMV (Synchronized Intermittent Mandatory Ventilation)
  • MMV (Mandatory Minute Volume Ventilation)
  • CPAP (Continuous Positive Airway Pressure)
  • PS (Pressure Support)
  • PCV+ (Pressure-Controlled Ventilation plus)
  • Airway Pressure Release Ventilation)

 

Measured Values Displayed

  • Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
  • Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
  • Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTASB (VTPS) (0 to 3999 mL)
  • Breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)
  • O2 concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
  • Resistance ((0.0 to 600 mbar/L/s)(cmH2O/L/s)
  • Compliance ((0.0 to 300 mL/mbar)(mL/cmH2O)
  • Breathing gas temperature: 18°to 51°C

 

User Interface

  • Instructions: Detailed voice prompts and visual icons guide responder through use of the defibrillator
  • CPR coaching: Voice coaching for adult and infant/child CPR provides instructions and audio cues for the appropriate number, rate and depth of chest compressions, as well as for each breath
  • Controls: Green On/Off button, blue i-button, orange Shock button, optional Infant/Child key
  • Indicators: Ready light, blue i-button, caution light, illuminated pads, icons, Shock button lights up when shock is advised

 

Date Recording and Transmission

  • Infrared : Wireless transmission of event data to a Smartphone or PC, using the IrDA protocol
  • HeartStart Event Review Data management software (optional) for download and review of Software: data retrieved through defibrillator’s infrared data port
  • Data stored: First 15 minutes of ECG and the entire incident’s events and analysis decisions.

 